Fluke 378 FC 1000A Non-Contact Voltage True-RMS AC / DC Clamp Meter With iFlex

Shop all Fluke

SKU: ME.EL.CL.00012

Model: Fluke378

Roll over image to zoom zoom_in
  1. Fluke 378 FC 1000A Non-Contact Voltage True-RMS AC / DC Clamp Meter With iFlex
  2. Fluke 378 FC 1000A Non-Contact Voltage True-RMS AC / DC Clamp Meter With iFlex
  3. Fluke 378 FC 1000A Non-Contact Voltage True-RMS AC / DC Clamp Meter With iFlex
  4. Fluke 378 FC 1000A Non-Contact Voltage True-RMS AC / DC Clamp Meter With iFlex
Video

  • Weight: 463 Grams
  • Product Type: Clamp Meters
  • Battery Life: 200 hour
  • Jaw Opening: 34 mm
  • Storage Temperature: -40 °C to 60 °C
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

94210.02 (Incl. of all taxes)

79839+ ₹14371.02 GST (18%)

MRP ₹117410

SAVE 32%



12 Business Days

1 Pcs

90303100

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

Fluke 378 Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

Complete 3-Phase Measurements In Quick, Easy Steps:

  • Complete 3-phase voltage and current tests in 3 easy steps
  • Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
  • Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
  • Phase rotation auto-calculated and shown on the Fluke Connect software
  • No more hand-written notes or complicated math.

Voltage And Current Measurements With FieldSense™ Technology:

The Fluke 378 true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.

Power Quality Indicator Shows Whether A Problem Is In The Equipment Or The Power Line:

The 378 clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.

Measure Extremely High Current With iFlex® Probe:

The included iFlex flexible current probe lets you measure ac current as high as 2500 A. Crowded wiring cabinets and large conductors are easily measured with the iFlex probe.

Easy To See, Easy To Use With Included Tools:

Your job will get easier when you use the 378 clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.

Record, Analyze, Share Results With Fluke Connect® Software:

With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.


Features:

  • Measure voltage and current with your clamp jaw
  • Faster, safer testing - all without touching a live wire - using FieldSense™ technology
  • Power quality indicator shows whether equipment or power line is faulty
  • Complete 3-phase voltage and current tests in 3 quick steps


What's Included In This Package:

  • Clamp Meter
  • Flexible Probe
  • ToolPak™ Magnetic Meter Hanger
  • Test Leads
  • TwistGuard™ Test Probes
  • Black Grounding Clip
  • Premium Carrying Case
  • Quick Reference Guide


Specifications:

Electrical
AC Current: Jaw
Range999.9 A
Resolution0.1 A
Accuracy2 % ±5 digits (45 Hz to 66 Hz)
Crest Factor (50/60 Hz)3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range2500 A
Resolution1 A (≤2500 A) 0.1 A (≤999.9 A)
Accuracy3 % ±5 digits (5 Hz to 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. >2
Position Sensitivity
Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)± 1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2 % ±5 digits1
[1]When using the ZERO function to compensate for offsets
AC Voltage: Field Sense
Range1000 V
Resolution1 V (≤1000V)
Accuracy≤4/0 AWG3 % ±5 digits (45 Hz to 66 Hz)
≥4/0 AWG5 % ±5 digits (45 Hz to 66 Hz)
Position wire as close as possible to jaw opening (see illustration).
AC Voltage: Test Leads
Range600.0 V 1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range600.0 V
1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1 % ±5 digits
Amps Frequency: Jaw
Range45 Hz to 66 Hz
Resolution0.1 Hz
Accuracy0.5 % ±5 digits
Trigger Level5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A
Amps Frequency: Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % ±5 digits
Trigger Level5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz,≥25 A
Resistance
Range60.00 k?
6000 ?
600.0 ?
Resolution0.1 ? (≤600.0 ?)
1 ? (≤6000 ?)
10 ? (≤60.00 k?)
Accuracy1 % ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy1 % ±4 digits
Environmental
Operating Humidity (without condensation)Non condensing (<10 °C)
≤90 % RH (10 °C to 30 °C)
≤75 % RH (30 °C to 40 °C)
≤45 % RH (40 °C to 50 °C)
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C >28 °C or <18 °C
Ingress ProtectionIEC 60529: IP30 (jaw closed)
Operating Altitude2000 m
Storage Altitude12 000 m
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
GeneralIEC 61010-1: Pollution degree 2
MeasurementIEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
Current Clamp for Leakage Current MeasurementsIEC 61557-13: Class 2, ≤30 A/m
Wireless Radio
Radio Frequency CertificationFCC ID: T68-FBLE IC:6627A-FBLE
Frequency Range2405 MHz to 2480 MHz
Output Power<100 mW
Radio Frequency DataRadio Frequency Data For Class A Devices
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision.

Specifications

SKUME.EL.CL.00012
Product TypeClamp Meters
Model NoFluke378
General Maximum Voltage between any Terminal and Earth Ground 1000 V
Battery 2 AA IEC LR6 alkaline
Battery Life 200 hour
Display Dual readout
Automatic Power Off 20 minutes
Size (L x W x H) 274 mm x 86 mm x 47 mm
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length (head to electronics connector) 1.8 Mtr
Rogowski Coil Length 450 mm
Operating Temperature -10 °C to 50 °C
Storage Temperature -40 °C to 60 °C

You May Also Like

Shop By Related Categories

Fluke 378 FC 1000A Non-Contact Voltage True-RMS AC / DC Clamp Meter With iFlex

Visit Fluke Store keyboard_double_arrow_right

94210.02 (Incl. of all taxes)

79839+ ₹14371.02 GST (18%)

MRP ₹117410

SAVE 32%