Fluke 355 2000A True-RMS AC / DC Clamp Meter
- Weight: 814 Grams
- Product Type: Clamp Meters
- Test leads: Rated to 1000 V
- Jaw size: 58 mm (2.28 in)
- IP rating: 42 (indoor use only)
- receiptGST Invoice
- headphonesCustomer Service
- lockSecure Payments
- policyReturns & Warranty
- home_pinOrder Tracking
- paymentsBuy in Installments
₹165128.02 (Incl. of all taxes)
₹139939+ ₹25189.02 GST (18%)
MRP ₹205792
SAVE 32%
12 Business Days
1 Pcs
90303900
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
Highlights
Confidently take reliable readings with the True RMS, Fluke 355 digital clamp meter the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
Easy To Use All-In-One Tool:
- High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
- Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
Features:
- Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
What's Included In This Package:
- 355 2000 A Clamp Meter
- (1 pair) TL224 1.5 m silicone rubber test leads
- (1 pair) TP2 test probes
- (1 pair) AC285 alligator clips
- 6 AA batteries (Installed)
- C43 soft carrying case
- Quick Reference Guide
Electrical Specifications:
Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
Resolution | 10 mA / 100 mA / 1 A | |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits | |
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A | |
Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC rms |
Resolution | 10 mA / 100 mA / 1 A | |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits | |
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) | Range | 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC |
Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits | |
Trigger level for Hz filter OFF | 0.25 V / 6 V | |
Trigger level for Hz filter ON | 0.25 V / 6 V | |
Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) | Range | 4 V / 40 V / 400 V / 600 V ac rms |
Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits | |
Trigger level for Hz filter OFF | 0.050 V / 0.25 V / 6 V | |
Trigger level for Hz filter ON | 0.050 V / 0.25 V / 6 V | |
Ohms measurement | Range | 4 kΩ / 40 kΩ / 400 kΩ |
Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | |
Accuracy | 1.5% + 5 digits | |
Continuity beeper | On at ≤ 30 Ω Off at ≥ 100 Ω | |
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |
Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts | |
Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts | |
Trigger level | Refer to current and voltage tables | |
1. Add 2% to error spec for CF > 2 |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision.
Specifications
SKU | HA.AU.CL.00017 |
---|---|
Product Type | Clamp Meters |
Model No | Fluke355 |
Test leads | Rated to 1000 V |
Jaw size | 58 mm (2.28 in) |
Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 |
Battery life (with typical usage, backlight off) | 100 hours |
Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) |
Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Operating temperature | 32°F to +122°F (0°C to +50°C) |
Storage temperature | -4°F to 140°F (-20°C to +60°C) |
Operating humidity | 0 to 95% (non-condensing) |
Operating altitude | 2000 Mtr |
Storage altitude | 10,000 Mtr |
IP rating | 42 (indoor use only) |
Drop test requirements | 1 Mtr |
Temperature coefficients Current | 0.1% of reading per °C outside 22°C to 24°C |
Temperature coefficients Voltage | 0.1% of reading per °C outside 22°C to 24°C |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325 |
You May Also Like
Shop By Related Categories
Fluke 355 2000A True-RMS AC / DC Clamp Meter
Visit Fluke Store keyboard_double_arrow_right₹165128.02 (Incl. of all taxes)
₹139939+ ₹25189.02 GST (18%)
MRP ₹205792
SAVE 32%